๐—›๐—ฒ๐—ฎ๐˜ ๐—ฃ๐˜‚๐—บ๐—ฝ๐˜€: ๐—›๐—ผ๐˜„ ๐˜๐—ผ ๐—ฆ๐—ถ๐˜‡๐—ฒ ๐˜†๐—ผ๐˜‚๐—ฟ ๐—ฆ๐˜†๐˜€๐˜๐—ฒ๐—บ In previous post [https://lnkd.in/e_7gryEA], we learned about ๐™ƒ๐™š๐™–๐™ฉ ๐™‹๐™ช๐™ข๐™ฅ๐™จ and their basic operating principle In this post, I will dive into the technical details of Heat Pumps and proper system sizing. I will work backward from monthly natural gas bills, so you don't need to be a mechanical engineer or HVAC technician to follow this basic math. For this analysis, I am using the ๐—Ÿ๐—ฌ๐—ก๐—ซโ„ข ๐Ÿญ๐Ÿด ๐˜๐˜ฏ๐˜ท๐˜ฆ๐˜ณ๐˜ต๐˜ฆ๐˜ณ ๐˜ˆ๐˜ช๐˜ณ ๐˜๐˜ฆ๐˜ข๐˜ต ๐˜—๐˜ถ๐˜ฎ๐˜ฑ, model# ๐Ÿฐ๐—›๐—ฃ๐Ÿญ๐Ÿด๐—ฉ๐Ÿฏ๐Ÿฒ๐—ฃ [1] ๐‘ฏ๐’†๐’‚๐’• ๐‘ท๐’–๐’Ž๐’‘ ๐‘บ๐’š๐’”๐’•๐’†๐’Ž ๐‘บ๐’Š๐’›๐’Š๐’๐’ˆ For homeowners with existing natural gas furnace, you can follow along with your own numbers. Otherwise, and if you have no previous data, you can follow these rule of thumbs based on your home square footage ๐˜๐˜— ๐˜™๐˜ข๐˜ต๐˜ช๐˜ฏ๐˜จ = ๐‘˜ ย x ๐Ÿฎ๐Ÿฌ.๐Ÿฑ ๐ต๐‘ก๐‘ขโ„Ž x ๐‘ ๐‘ž.๐‘“๐‘ก Where ๐‘˜ is a scaling factor based on your ๐’๐’๐’„๐’‚๐’ย average Temperature LO's. โš  It's important to understand proper system sizing. Otherwise, you may end up with an oversized system which costs more, or undersized system that runs 24/7, wastes money and can't keep your home warm ๐‘ด๐’†๐’•๐’‰๐’๐’…๐’๐’๐’๐’ˆ๐’š 1. Tabulate your Natural Gas monthly consumption, I used publicly available OEB Bill Calculator [2] 2. Convert Energy content to ๐—š๐—, Column "C" 3. Convert Energy content to ๐— ๐— ๐—•๐˜๐˜‚, Column "D" ๐Ÿ’ก ๐˜”๐˜”๐˜‰๐˜ต๐˜ถ = ๐˜ฐ๐˜ฏ๐˜ฆ ๐˜ฎ๐˜ช๐˜ญ๐˜ญ๐˜ช๐˜ฐ๐˜ฏ ๐˜‰๐˜ต๐˜ถ (British Thermal Units) 4. Compute ๐——๐—ฎ๐—ถ๐—น๐˜† ๐—•๐˜๐˜‚๐—ตย based on ๐Ÿญ๐Ÿฎ ๐—ต๐—ผ๐˜‚๐—ฟ๐˜€ย run-time, Column "E" ๐Ÿ‘‰ ๐˜‹๐˜ข๐˜ช๐˜ญ๐˜บ ๐˜‰๐˜ต๐˜ถ๐˜ฉ = (๐˜”๐˜”๐˜‰๐˜ต๐˜ถ ๐˜น 10^6) รท (30 ๐˜ฅ๐˜ข๐˜บ๐˜ด) รท (12๐˜ฉ๐˜ฐ๐˜ถ๐˜ณ๐˜ด)ย  ๐˜ฝ๐™ฉ๐™ช๐™: reads British Thermal Units per hour This rating tells you how much ๐’•๐’‰๐’†๐’“๐’Ž๐’‚๐’ ๐’†๐’๐’†๐’“๐’ˆ๐’š can be extracted in one hour of run-time 5. Convert ๐˜ฝ๐™ฉ๐™ช๐™ to ๐™๐™ค๐™ฃ๐™จ, Column "F" ย ย ๐˜›๐˜ฐ๐˜ฏ๐˜ด = ๐˜‰๐˜ต๐˜ถ๐˜ฉ / 12,000 6. Size your heat pump with maximum computed tons For example, January has a maximum gas consumption of ๐Ÿฐ๐Ÿญ๐Ÿต๐—บยณ Assuming a run-time of 12hours a day, your heat pump system rating must be at a minimum 41,085๐˜ฝ๐™ฉ๐™ช๐™ = 41.1๐™ ๐˜ฝ๐™ฉ๐™ช๐™ =3.42๐™๐™ค๐™ฃ๐™จ ๐Ÿ‘‰ A Heat Pump size of ๐Ÿฏ.๐Ÿฒ ๐—ง๐—ผ๐—ป๐˜€ย is chosen. There you have it, now you know how to size your Heat Pump system. Easy-peasy! In my next post, I will walk you through the ๐‘›๐‘ข๐‘š๐‘๐‘’๐‘Ÿ๐‘ , ๐‘Ž๐‘›๐‘Ž๐‘™๐‘ฆ๐‘ ๐‘–๐‘  and ๐˜ช๐˜ฏ๐˜ด๐˜ช๐˜จ๐˜ฉ๐˜ตย from this post, the implications of sub-Zero temperatures and how to read the table/charts below ๐Ÿ˜Ž --- Related posts [1]๐—›๐—ฒ๐—ฎ๐˜ ๐—ฃ๐˜‚๐—บ๐—ฝ: ๐—œ๐—ป ๐—Ÿ๐—ฎ๐˜†๐—บ๐—ฒ๐—ป ๐—ง๐—ฒ๐—ฟ๐—บ๐˜€ ๐Ÿ”—https://lnkd.in/e_7gryEA [2] ๐—–๐—ฎ๐—ฟ๐—ฏ๐—ผ๐—ป ๐—ง๐—ฎ๐˜…: ๐—ง๐—ต๐—ฒ ๐—ฅ๐—ผ๐—ฎ๐—ฑ ๐—ง๐—ผ ๐—›๐˜†๐—ฝ๐—ฒ๐—ฟ ๐—œ๐—ป๐—ณ๐—น๐—ฎ๐˜๐—ถ๐—ผ๐—ป ๐Ÿ”—https://lnkd.in/exjsjHrK Joseph Fournier Tom Kirkman Mark Turnbull, MPM, MEng Renate Siekmann ๐Ÿ‡จ๐Ÿ‡ฆ ๐Ÿ‡บ๐Ÿ‡ธ PMP, P.Eng, Greenbelt โšก๏ธAdam

  • No alternative text description for this image
Richard Piekarz

Retired from Rockwell Automation

2mo

Based on your zone why would you put a heat pump in when efficiency at low temp is so poor and when it does get hot and you short cycle the units will kill itself in less than 2 years

Tom Kirkman

Freedom of Thought Enthusiast

2mo

Easier to just use natural gas to heat.

Most Canadians would have to multiple heating sources for the winter. Make the weather tax big enough and the opex avoidance might justify doing so, but only act to drive new home prices even further for first time home buyers.

Frank V.

RMC retired, veteran, 2007 Emerald award, life member P. Eng

2mo

Ahmad (AJ) A. Would love a copy

Frank V.

RMC retired, veteran, 2007 Emerald award, life member P. Eng

2mo

Thanks for posting,

Alexandru Armasu

Founder & CEO, Group 8 Security Solutions Inc. DBA Machine Learning Intelligence

2mo

Appreciate your contribution!

See more comments

To view or add a comment, sign in

Explore topics